INFLUENCE OF THE BLOOD FLOW THROUGH THE CAPILLARY ON THE MAIN PARAMETERS OF ERYTHROCYTES
Abstract and keywords
Abstract (English):
The trends in personalized medicine lead to the necessity of determining the normal range of biological parameters for each individual. This task requires high precision in the obtained parameters and frequent measurements. To ensure high accuracy in determining the morphological and functional parameters of blood cells, the method of scanning flow cytometry (SFC) has proven to be effective. Within this study, a needle-free venipuncture system is being developed to provide more comfortable conditions for blood collection during frequent monitoring of one's parameters. However, although such a system allows for much smaller skin punctures than a needle, the question arises as to whether these small openings can affect the blood cell parameters measured by SFC. This study identified the first potential factor influencing blood cell parameters - shear stress. The behavior of erythrocyte parameters was investigated as needles of different diameters passed through them. COMSOL modeling was conducted to analyze the distribution of forces acting on the surface of an ellipsoid (as a model for platelets and erythrocytes) in two scenarios: free cell movement in a capillary and for a cell attached to a substrate.

Keywords:
erythrocytes, anion exchange, shear stress, scanning flow cytometer
Text
Publication text (PDF): Read Download
References

1. Robinson J.P., Roederer M. Flow cytometry strikes gold. Science, 2015, vol. 350, iss. 6262, pp. 739-740, doi:https://doi.org/10.1126/science.aad6770.

2. Giesecke C., Feher K., Von Volkmann K., Kirsch J., Radbruch A., Kaiser T. Determination of background, signal-to-noise, and dynamic range of a flow cytometer: A novel practical method for instrument characterization and standardization: Determination of Flow Cytometer’s SNR and DNR. Cytometry, 2017, vol. 91, iss. 11, pp. 1104-1114, doi:https://doi.org/10.1002/cyto.a.23250.

3. Yastrebova E.S., Konokhova A.I., Strokotov D.I., Karpenko A.A., Maltsev V.P., Chernyshev A.V. Proposed Dynamics of CDB3 Activation in Human Erythrocytes by Nifedipine Studied with Scanning Flow Cytometry. Cytometry, Part A, doi:https://doi.org/10.1002/cyto.a.23918.

4. Gilev K.V. et al. Advanced consumable-free morphological analysis of intact red blood cells by a compact scanning flow cytometer. Cytometry, Part A, 2017, vol. 91, iss. 9, pp. 867-873, doi:https://doi.org/10.1002/cyto.a.23141.

5. Lee H., Kim G., Lim C., Lee B., Shin S. A simple method for activating the platelets used in microfluidic platelet aggregation tests: Stirring-induced platelet activation. Biomicrofluidics, 2016, vol. 10, iss. 6, p. 064118, doi:https://doi.org/10.1063/1.4972077.

6. Shankaran H., Alexandridis P., Neelamegham S. Aspects of hydrodynamic shear regulating shear-induced platelet activation and self-association of von Willebrand factor in suspension. Blood, 2003, vol. 101, iss. 7, pp. 2637-2645, doi:https://doi.org/10.1182/blood-2002-05-1550.

7. Rahman S.M., Eichinger C.D., Hlady V. Effects of upstream shear forces on priming of platelets for downstream adhesion and activation. Acta Biomaterialia, 2018, vol. 73, pp. 228-235, doi:https://doi.org/10.1016/j.actbio.2018.04.002.

8. Sheriff J., Soares J.S., Xenos M., Jesty J., Bluestein D. Evaluation of Shear-Induced Platelet Activation Models Under Constant and Dynamic Shear Stress Loading Conditions Relevant to Devices. Ann Biomed Eng, 2013, vol. 41, iss. 6, pp. 1279-1296, doi:https://doi.org/10.1007/s10439-013-0758-x.

9. Koutsiaris A.G. et al. Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo. Biorheology, 2007, vol. 44, iss. 5-6, pp. 375-386.

10. Ilkan Z., Wright J.R., Goodall A.H., Gibbins J.M., Jones C.I., Mahaut-Smith M.P. Evidence for shear-mediated Ca2+ entry through mechanosensitive cation channels in human platelets and a megakaryocytic cell line. Journal of Biological Chemistry, 2017, vol. 292, iss. 22, pp. 9204-9217, doi:https://doi.org/10.1074/jbc.M116.766196.

11. Alemu Y., Bluestein D. Flow-induced Platelet Activation and Damage Accumulation in a Mechanical Heart Valve: Numerical Studies. Artificial Organs, 2007, vol. 31, iss. 9, pp. 677-688, doi:https://doi.org/10.1111/j.1525-1594.2007.00446.x.

12. Kroll M.H., Hellums J.D., McIntire L.V., Schafer A.I., Moake J.L. Platelets and shear stress. Blood, 1996, vol. 88, iss. 5, pp. 1525-1541.

13. Barthes-Biesel D. Motion of a spherical microcapsule freely suspended in a linear shear flow. J. Fluid Mech., 1980, vol. 100, iss. 4, pp. 831-853, doi:https://doi.org/10.1017/S0022112080001449.

14. Barthes-Biesel D., Rallison J.M. The time-dependent deformation of a capsule freely suspended in a linear shear flow. J. Fluid Mech., 1981, vol. 113, iss. 1, p. 251, doi:https://doi.org/10.1017/S0022112081003480.

15. Vahidkhah K., Diamond S.L., Bagchi P. Platelet Dynamics in Three-Dimensional Simulation of Whole Blood. Biophysical Journal, 2014, vol. 106, iss. 11, pp. 2529-2540, doi:https://doi.org/10.1016/j.bpj.2014.04.028.

16. Doddi S.K., Bagchi P. Three-dimensional computational modeling of multiple deformable cells flowing in microvessels. Phys. Rev. E, 2009, vol. 79, iss. 4, p. 046318, doi:https://doi.org/10.1103/PhysRevE.79.046318.

17. Gilev K.V., Yurkin M.A., Chernyshova E.S., Strokotov D.I., Chernyshev A.V., Maltsev V.P. Mature red blood cells: from optical model to inverse light-scattering problem. Biomed Opt Express, 2016, vol. 7, iss. 4, pp. 1305-1310, doi:https://doi.org/10.1364/BOE.7.001305.

18. Yastrebova E.S. et al. Erythrocyte lysis and angle‐resolved light scattering measured by scanning flow cytometry result to 48 indices quantifying a gas exchange function of the human organism. Cytometry Pt A, 2022, doi:https://doi.org/10.1002/cyto.a.24554.


Login or Create
* Forgot password?